Kane May Combustion Analyzer & (KM900CO/P) CO Detector (Ruggedized)
The KM900CO/P measures CO and calculates CO2, boiler efficiency, excess air losses and the O2 and CO/CO2 ration - "The Poison Index" - to give complete readings for effective boiler analysis. This hand-held analyzer is easy to use for residential or commercial flue gas measurement and analysis.
Operates on all boiler types and displays up to eight parameters simulateously, showing measurements and calculations of fossil fuel appliances efficiency and pollution. Memory can store up to 150 readings and can be transferred to a printer or PC. The printout displays the date / time of each measurement as well as personalized information such as company name and telephone number.
- Large four-line LED display
- Battery Charger / Main Adapter
- Flue Probe
- Water trap / Particle Filter Assembly
- Replacement Particle Filter
- Protective Rubber Sleeve (ruggedized)
- Long-life rechargeable battery
- Large Cordura carrying case
- 0 - 10,000 ppm H2 compensated CO sensor
- Infrared printer port
- One year limited warranty - 2 year limited warranty on O2 sensor Temp Measurement Parameter Resolution Accuracy Range Flue Temperature 1.0ºC/F +2.0ºC +0.3% reading 0-600ºC
32-1112ºF Temperature (Nett) 1.0ºC/F +2ºC +0.3% reading 0-50ºC /
32-122ºF Gas Measurement Parameter Resolution Accuracy Range Oxygen 0.1% +0.2% 0.21% Carbon Monoxide 1ppm,mg/m3 +20ppm<400ppm
+5% <5000ppm
+10% <5000ppm 0-10,000ppm
0-12,000mg/m3 Nitric Oxide
(optional) 1ppm,mg/m3 +5ppm <100ppm
+5% >100ppm 0-5000ppm
0-6700mg/m3 Draught
(optional) 0.1mbar +5.0% full scale 150mbar Carbon Dioxide 0.1% +0.3% reading 0-99.9% Efficiency* 0.1% +1.0% reading 0-99.99% Losses* 0.1% +1.0% reading 0-99.99% Excess Air* 0.1% +0.2% 0-2885.0% Temp (Nett) 1.0°C/F +2°C +0.3% reading 0-600°C/32-1112°F CO/CO2 Ratio 0.0001 +0.0001 0-0.9999 Poison Index 0.01% +0.02 0-99.99 Pre-Programmed Fuels Natural gas, Propane, Butane, Light Oil, Town Gas, Gascor, Kinsale Gas, Heavy Oil, Anthracite, Coke, Coal Dimension: Weight: 202lbs/1Kg
Handset: 8.6'' x 2.2'' x 4.8''/ 220mm x 55mm x 120mm
Probe (KMCP2): L420mm x Dia8mm with stainless steel shaft, type K thermocouple and 3m neoprene hose Ambient Operating Range 0°C to + 40°C /
10% to 90% RH non condensing Power Supply AC Adapter Input: 110Vac / 220Vac nominal
Output: 12Vac off load Battery Life >8 hours from full charge
|
WillyFogg.com doesn't sell any of the products listed on our site.
To buy a product you need to use the link provided and visit the seller's site.
|